Monitor, Ground Hub, 120Vac, N. America
- Monitors AC Outlet's Wiring and Path to Earth Ground
Continuously monitors the path to ground integrity of the outlet meeting the ANSI/ESD S6.1 requirement for verifying wiring orientation. - Constant Visual Indicator
LEDs provide a visual indication that outlet is properly wired for grounding purposes of an ESD Control Plan. - Visual and Audio Fault Alarms
Alarms activate instantly when a failure occurs, alerting user and supervisor of a problem. - Six Banana Jacks and Six Screws for #8 Ring Terminals
Provides numerous groundable points for wrist straps, mats, carts, tools, and other items. May also be connected to other grounding hubs. See Part# 09837 - Made in The United States of America
This item is made and stocked in Chino, CA
"The grounding system must be verified periodically at the frequency established in a user defined ESD Control Program Plan." [Grounding ANSI/ESD S6.1-2009 section 6.2 Verification Frequency]
"All of the grounding conductors from each of the ESD technical elements (excluding level 2 technical elements) used within an EPA shall be terminated at the same electrically equivalent point. The common point ground may be a terminal strip, bus bar or any other convenient configuration that is, within itself, electrically continuous to no greater than 1 ohm measured from point to point with an ohmmeter". [Grounding ANSI/ESD S6.1-2009 section 5.2.1 Common Point Ground]